Home Categories Send inquiry

Deye 8kw SUN-8K-SG01LP1-US Split Phase Hybrid Inverter

The Deye hybrid grid inverter is not limited to just European and Australian standards, it also includes American standards. In order to comply with the market standards in North and South America, DeYe has developed a series of products specifically designed for the American market. SUN-8K-SG01LP1-US,SUN-7.6K-SG01LP1-US,SUN-6K-SG01LP1-US,SUN-5K-SG01LP1-US。 This series is a single-phase low voltage (48V) hybrid inverter that enables enhanced energy independence and maximizes self-consumption through export limit feature and “time of use” function. With the frequency droop control algorithm, this series product supports single phase and three phase parallel application, and the Max. parallel units is up to 16pcs.
  • Colorful touch LCD, IP65 protection degree
  • 6 time periods for battery charging/discharging
  • Max. charging/discharging current of 190A
  • Max.16pcs parallel
  • DC couple and AC couple to retrofit existing solar system
  • Support storing energy from diesel generator
  • Max. battery charge efficiency of 95.4%
  • Unique Smart Load application and Grid peak shaving function
  • 4ms fast transfer from on-grid to off-grid mode, ensuing the traditional fixed frequency air conditioner works well
  • Certified by UL, CE, IEC, VDE, NRS, VFR, AS4777.2, CEI and INMETRO etc.
Model SUN-5K-SG01LP1-US SUN-6K-SG01LP1-US SUN-7.6K-SG01LP1-US/EU SUN-8K-SG01LP1-US-EU
Battery Input Data
Battery Type Lead-acid or Li-lon
Battery Voltage Range (V)  40~60
Max. Charging Current (A)  120 135 190 190
Max. Discharging Current (A)  120 135 190 190
External Temperature Sensor  Yes
Charging Curve  3 Stages / Equalization
Charging Strategy for Li-Ion Battery  Self-adaption to BMS
PV String Input Data 
Max. DC Input Power (W)  6500 7800 9880 10400
Rated PV Input Voltage (V)  370 (125~500)
Start-up Voltage (V)  125
MPPT Voltage Range (V)  150-425
Full Load DC Voltage Range (V)  300-425 200-425
PV Input Current (A)  13+13 26+13 26+26
Max. PV ISC (A)  17+17 34+17 34+34
Number of MPPT / Strings per MPPT  2/1+1 2/2+1 2/2+2
AC Output Data 
Rated AC Output and UPS Power (W)  5000 6000 7600 8000
Max. AC Output Power (W)  5500 6600 8360 8800
AC Output Rated Current (A)  20.8/24 25/28.8 31.7/36.5 34.5 33.3/38.5 36.4
Max. AC Current (A)  22.9/26.4 27.5/31.7 34.8/40.2 38 36.7/42.3 40
Max. Continuous AC Passthrough (A)   40 50
Peak Power (off grid)  0.8 leading to 0.8 lagging
Output Frequency and Voltage  50 / 60Hz; L1/L2/N(PE) 120/240Vac (split phase), 208Vac (2/3 phase), L/N/PE 220/230Vac (single phase)
Grid Type  Split phase; 2/3 phase; Single Phase
DC injection current (mA)  THD<3% (Linear load<1.5%)
Efficiency
Max. Efficiency  97.60%
Euro Efficiency  97.00%
MPPT Efficiency  99.90%
Protection
Integrated  PV Input Lightning Protection, Anti-islanding Protection, PV String Input Reverse Polarity Protection, Insulation Resistor Detection, Residual Current Monitoring Unit, Output Over Current Protection, Surge protection
Certifications and Standards 
Grid Regulation  CEI 0-21, VDE-AR-N 4105, NRS 097, IEC 62116, IEC 61727, G99, G98, VDE 0126-1-1, RD 1699, C10-11
Safety EMC / Standard  IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2
General Data 
Operating Temperature Range (℃)  -45~60℃, >45℃ derating
Cooling  Smart cooling
Noise (dB)  <30 dB
Communication with BMS  RS485; CAN
Weight (kg)  32
Size (mm)  420W×670H×233D
Protection Degree  IP65
Installation Style  Wall-mounted
Warranty  5 years